mini-split installation

Wes took the time to explain options & was the only one to correctly size the unit according to line size & construction.


Response from Ideal Air Conditioning and Insulation:

Thanks so much for the feedback, Phillip! So glad we could help!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for fountain hills, az

Matthew B.

Matthew B. Job Checkin

Performed the maintenance on the mini split. The homeowner did not want the new unit maintenance at this time.

Performed the maintenance on the mini split. The homeowner did not want the new unit maintenance at this time. Performed the maintenance on the mini split. The homeowner did not want the new unit maintenance at this time.

Chris M.

Chris M. Job Checkin

Flue pipe repair estimate


Matthew B.

Matthew B. Job Checkin

DESCRIPTION Replace Indoor Coil Remove leaky damaged coil and pump down refrigerant into out door unit Install new OEM coil + filter drier and purge with Nitrogen while brazing Complete leak test with Nitrogen to 500 PSI Evacuate system to below 500 Microns Check charge and add refrigerant as needed. If system is flat add refrigerant charges per pound as needed Record super heat, subcool and temperature split Non Members: 90 day parts + labor warranty on all repairs Cool home members: 2 year parts + labor warranty on all repairs

DESCRIPTION
Replace Indoor Coil
Remove leaky damaged coil and pump down refrigerant into out door unit
Install new OEM coil + filter drier and purge with Nitrogen while brazing
Complete leak test with Nitrogen to 500 PSI
Evacuate system to below 500 Microns
Check charge and add refrigerant as needed. If system is flat add refrigerant charges per pound as needed
Record super heat, subcool and temperature split
Non Members: 90 day parts + labor warranty on all repairs
Cool home members: 2 year parts + labor warranty on all repairs
DESCRIPTION
Replace Indoor Coil
Remove leaky damaged coil and pump down refrigerant into out door unit
Install new OEM coil + filter drier and purge with Nitrogen while brazing
Complete leak test with Nitrogen to 500 PSI
Evacuate system to below 500 Microns
Check charge and add refrigerant as needed. If system is flat add refrigerant charges per pound as needed
Record super heat, subcool and temperature split
Non Members: 90 day parts + labor warranty on all repairs
Cool home members: 2 year parts + labor warranty on all repairs

Nixa G.

Nixa G. Job Checkin

R- 410a Adjust Refrigerant level: Every pound after 1st RECOMMEND LEAK SEARCH BEFORE ADJUSTING REFRIGERANT CHARGE Purge gauges to ensure no non-condensables enter system Use digital scale to weigh in refrigerant Adjust according to units TP chart and super heat and sub cool

R- 410a Adjust Refrigerant level: Every pound after 1st
RECOMMEND LEAK SEARCH BEFORE ADJUSTING REFRIGERANT CHARGE
Purge gauges to ensure no non-condensables enter system
Use digital scale to weigh in refrigerant
Adjust according to units TP chart and super heat and sub cool R- 410a Adjust Refrigerant level: Every pound after 1st
RECOMMEND LEAK SEARCH BEFORE ADJUSTING REFRIGERANT CHARGE
Purge gauges to ensure no non-condensables enter system
Use digital scale to weigh in refrigerant
Adjust according to units TP chart and super heat and sub cool

Charles B.

Charles B. Job Checkin

I found unit was pitched away from my drain. I re leveled air handler and verified good drainage.

I found unit was pitched away from my drain. I re leveled air handler and verified good drainage. I found unit was pitched away from my drain. I re leveled air handler and verified good drainage.

Chris M.

Chris M. Job Checkin

Air balance


Charles B.

Charles B. Job Checkin

Arrived to home Found short in 24V Blown control fuse Extensive rust throughout system Standing water inside AHU Primary pan no longer sloped toward drain Unit is level *Needs energy audit done **recommend replacement or additional repairs Repair

Arrived to home
Found short in 24V
Blown control fuse
Extensive rust throughout system
Standing water inside AHU
Primary pan no longer sloped toward drain
Unit is level

*Needs energy audit done
**recommend replacement or additional repairs

Repair Arrived to home
Found short in 24V
Blown control fuse
Extensive rust throughout system
Standing water inside AHU
Primary pan no longer sloped toward drain
Unit is level

*Needs energy audit done
**recommend replacement or additional repairs

Repair

Eric  A.

Eric A. Job Checkin

- $2,000 IRA Federal Tax Credit System meets qualifications - Individual qualifications vary - May qualify for promotions, 0% for up to 60 months or low payment plans - Discount available for check payment *CLICK "VIEW MORE" on each line item to view included improvements

- $2,000 IRA Federal Tax Credit System meets qualifications - Individual qualifications vary

- May qualify for promotions, 0% for up to 60 months or low payment plans

- Discount available for check payment

*CLICK "VIEW MORE" on each line item to view included improvements - $2,000 IRA Federal Tax Credit System meets qualifications - Individual qualifications vary

- May qualify for promotions, 0% for up to 60 months or low payment plans

- Discount available for check payment

*CLICK "VIEW MORE" on each line item to view included improvements

Chris M.

Chris M. Job Checkin

Service call


Cristian  Z.

Cristian Z. Job Checkin

AC installation in Fountain Hills

AC installation in Fountain Hills AC installation in Fountain Hills

Chris M.

Chris M. Job Checkin

No answer


Chris M.

Chris M. Job Checkin

Site visit for duct mod

Site visit for duct mod Site visit for duct mod

Charles B.

Charles B. Job Checkin

Insulation installation in Fountain Hills. Air Barrier seal, Insulate to R38+, Insulate attic hatch


Charles B.

Charles B. Job Checkin

Arrived to home Spoke with Rob about issues Discussed current duct layout and detriment to system due to poor air flow Checked system Found bad condenser motor Found swelled capacitor Condenser fan motor Dual run cap - warranty


Charles B.

Charles B. Job Checkin

Arrived to home Found code 094 amongst others Shut off disconnect at CU and AHU breaker Waited 5 minutes and turned back on Found 65V between L1&L2 at disconnect Located breaker panel for CU Breaker showed the on position Shut off and turned back on Went to 205 then directly to 65 again Customer needs electrician to diagnose electrical issues Left disconnect off Need to return to start system once electrical is fixed